Professional Network Infrastructure

Structured Cabling Installation NJ

Clean, tested Cat6/6A cabling for medical offices. Fluke certified, CMP/riser compliant, with HIPAA-aligned network segmentation.

Right Cable, Right Space

We help you choose the right cable type for your facility

CMP (Plenum)

For air-handling spaces

Low-smoke, low-toxicity jacket used in air-handling spaces above drop ceilings. Required in plenum spaces per building code.

  • Above drop ceilings
  • Return-air spaces
  • Code-compliant for healthcare

CMR (Riser)

For vertical runs

Fire-resistant jacket for vertical cable runs between floors. More cost-effective than plenum where code allows.

  • Vertical risers
  • Between floors
  • Non-plenum spaces

Complete Cabling Services

Everything you need for a reliable network infrastructure

Cat6/6A Installation

TIA-568 terminations with labeled patch panels and keystones.

Fluke Certification

Every run tested and certified. PDF reports and as-built maps included.

Rack & Panel Design

MDF/IDF layout, cable management, UPS sizing, and grounding.

VLAN Segmentation

Separate networks for PHI, staff, guest, and IoT for HIPAA compliance.

Wi-Fi Heatmaps

AP placement optimization for complete coverage throughout your facility.

Documentation

Port maps, floor plan overlays, and complete as-built documentation.

Project Packages

Solutions sized for your practice

Biller Suite

6-12 drops, 1 AP, labeled patch panel, Fluke reports, guest Wi-Fi split.

1-day install typical

Get Quote
Popular

Small Clinic

12-36 drops, 2-4 APs, VLANs for PHI/staff/guest, UPS & rack dressing.

After-hours cutover included

Get Quote

Multi-Floor

Full MDF/IDF design, 36+ drops, fiber backbone, advanced security.

Project management included

Get Quote

Frequently Asked Questions

Cat6 vs Cat6A - what should we choose?

Cat6 handles 1 Gbps easily and 10 Gbps for shorter runs. Cat6A is better for new builds requiring 10 Gbps over longer distances. We size based on your EHR, imaging, and growth plans.

Do you provide Fluke test reports?

Yes - every run is labeled end-to-end and certified with a Fluke meter. You receive PDF reports plus an as-built map and port list.

How do you decide CMP vs CMR cable?

We verify ceiling return-air design and building policy to choose CMP for plenum spaces and CMR for risers - documented in the as-builts.

Do you work nights/weekends?

Yes - after-hours installs and cutovers to avoid clinic downtime. We coordinate with building access.

Ready to Upgrade Your Network?

Same-week surveys across Edison, Princeton, East Windsor, New Brunswick, and nearby areas.